Pulse oximeter

Additional Description

Features: * Three parameters:SpO2,Pulse Rate,Temperature * SpO2 waveform, PR strength display * 2.8 inch color LCD with real time display * Storage/Review trend data up to 3888 groups, data save time interval settable * Audio and visual alarm when parameters exceeded and sensor-off * Built-in rechargeable Li-ion battery, up to 8 hour running time * Automatic shutdown for power saving, shutdown time interval settable * Via USB to connect with the computer, unique software for telemonitoring by transmitting data synchronously via internet * Battery capacity indicatior and prompt when battery low Applications: Table Pulse Oximeter can be applied in the hospital’s operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment. Standard Packing List: Tabletop Pulse Oximeter main unit 1pc Adult finger SpO2 sensor 1pc AC power adaptor 1pc Communication cable 1pc The operator’s manual 1pc Surface TEMP probe Selectable Accessory: Child or neonatal finger/toe SpO2 sensor Specifications: 1. General Monitoring Parameters: SpO2、PR、PLETH、Pulse strength、TEMP Signal sockets:SpO2 socket、PR socket、TEMP socket、adaptor socket、PC communication socket 2. Display screen: Type: 240×320 dot matrix colour TFT LCD screen and LED screen LCD Display area: 44mm×59mm LED Display area: 167mm×79mm Backlight color: White 3. Parameter Specifications SpO2: Patient: Adult, child and neonate Range:0%~100% Resolution:1 % Accuracy: 2 %(90% ~100%), Unspecified (0%~ 69%) PR: Range:30 bpm~250bpm Resolution:1bpm Accuracy:1bpm 4. Electrical specifications Working Voltage: DC 6.0V~9.0V AC power adaptor Input: AC 100~240V, 50/60Hz, 0.7A Output: DC 5V,2.5A Internal battery Type: 2.8Ahr build-in Li-ion rechargeable battery Run Time: 15-hour continuous operation with a new, fully charged battery (environment temperature is 25℃) Recharge time: 8 hours Common 1.5V Battery Run Time: More than 5-hour continuous operation with a new battery (environment temperature is 25℃) 5. Working Environment Temperature Operation:0C ~ 45 C Transportation and storage:-20 C ~ 60 C Humidity Operation:15% ~95 %( non-condensing) Transportation and storage:10% ~ 95 % (non-condensing) Altitude Operation:86KPa~106KPa Transportation and storage:50KPa~106KPa 6. Packing Product Size: 280(W)*190(H)*100(D)MM Packing Size: 290(W)*200(H)*110(D)MM NW: 1000g

Product Inquiry

Pulse Oximeter

Handheld ECG monitor

Pulse Oximeter

Pulse oximeter

Handheld Multi-para. Patient Monitor